Definition of 'Intra-Aortic Balloon Pumping'

Counterpulsation in which a pumping unit synchronized with the patient's electrocardiogram rapidly fills a balloon in the aorta with helium or carbon dioxide in early diastole and evacuates the balloon at the onset of systole. As the balloon inflates, it raises aortic diastolic pressure, and as it deflates, it lowers aortic systolic pressure. The result is a decrease in left ventricular work and increased myocardial and peripheral perfusion.

More technical Information...

Mechanical circulatory support: a clinical reality.

29 Sep 2008 Mechanical circulatory support is becoming an alternative therapeutic option for patients in cardiogenic shock or advanced cardiac failure who cannot be improved by maximal medical therapy. More than 30 years of engineering development and clinical ... Read more...


Effects of intra-aortic balloon pumping on graft flow in coronary surgery: an intraoperative transit-time flowmetric study.

30 Aug 2008 BACKGROUND: We investigated hemodynamic effects of intra-aortic balloon pumping (IABP) in in-situ and aorta-coronary (A-C) grafts during coronary artery bypass grafting (CABG). METHODS: One hundred seventy-two grafts, including 84 in-situ left ... Read more...


Percutaneous ventricular assist devices for cardiogenic shock.

30 Aug 2008 Cardiogenic shock complicates up to 7% of ST-segment elevation myocardial infarctions and 2.5% of non-ST-segment elevation myocardial infarctions, with an associated mortality of 50% to 70%. Primary cardiac pump failure is followed by secondary ... Read more...

 

Learn Faster Today      Improve your study skills

Latest indexed articles for 'Intra-Aortic Balloon Pumping'

These are the very latest articles for this heading:

See a longer list of these articles.

Technical information about 'Intra-Aortic Balloon Pumping'

Definition: Counterpulsation in which a pumping unit synchronized with the patient's electrocardiogram rapidly fills a balloon in the aorta with helium or carbon dioxide in early diastole and evacuates the balloon at the onset of systole. As the balloon inflates, it raises aortic diastolic pressure, and as it deflates, it lowers aortic systolic pressure. The result is a decrease in left ventricular work and increased myocardial and peripheral perfusion.

Descriptor UI: D007423

Alternative terms: Intra-Aortic Balloon Pumping; Intra Aortic Balloon Pumping; Intraaortic Balloon Pumping; Balloon Pumping, Intraaortic; Pumping, Intraaortic Balloon; Pumping, Intra-Aortic Balloon; Balloon Pumping, Intra-Aortic; Pumping, Intra Aortic Balloon;

Allowable Qualifiers: adverse effects; classification; economics; education; history; instrumentation; legislation & jurisprudence; methods; mortality; nursing; psychology; rehabilitation; standards; trends; utilization; veterinary; statistics & numerical data; contraindications; ethics;

Tree Number: E04.050.215.400;

History Note: 86(77); was see under ASSISTED CIRCULATION 1977-85

Technical Notes: DF: IABP