|
|
| Research article summary (published 28 Feb 2000): |
Analysis of stress distribution in a screw-retained implant prosthesis.
Full Abstract
Four types of implant superstructures were screwed onto implant bodies, and the strains created around the implant bodies were compared and analyzed within the IMZ Implant System. Three IMZ implants were embedded in the center of a polyurethane block (30 x 40 x 30 mm), and a total of 16 superstructures was fabricated by 4 methods: 1-piece cast, 1-piece cast/split soldering, soldering, and passive fit. Six strain gauges were placed on the surface of the block 1 mm apart. Three embedded implants were numbered, and a fixed partial denture was placed on these implants and screwed by a torque wrench using 14.5 Ncm torque. This procedure was repeated 7 times for each fixed partial denture, and each created strain was measured when the last screw was tightened. In all fixed partial dentures, strains were produced around the implant bodies when screws retaining the prosthesis were tightened, and the strain was relieved with unscrewing. The magnitude of strain was greater with the 1-piece cast method or the section/solder method than with the soldering and passive-fit methods. Of the 2 soldering methods, when the screw on the middle implant was tightened before those on the terminal 2 implants, the magnitude of strain was lower with the soldering method than with the 1-piece cast/split soldering method. When the order of screw tightening was changed, there were significant differences in the magnitude of strain at each gauge with the soldering method. With the passive-fit method, no differences in the magnitude of strain attributable to the order of screw tightening could be detected. The magnitude of strain produced around a screw-retained implant prosthesis was significantly lower with the passive-fit method when compared to the other 3 fabricating methods. Furthermore, the implants prepared by the passive-fit method were not affected by the order of screw tightening.
Author information
Author/s: Watanabe, F (F); Uno, I (I); Hata, Y (Y); Neuendorff, G (G); Kirsch, A (A);
Affiliation: Department of Crown and Bridge Prosthodontics, Nippon Dental University, Niigata, Japan.
Journal and publication information
Publication Type: Comparative Study; Journal Article
Journal: The International journal of oral & maxillofacial implants (Int J Oral Maxillofac Implants), published in UNITED STATES. (Language: eng)
Reference: -2000 Mar-Apr; vol 15 (issue 2) : pp 209-18
Dates: Created 2000/06/01; Completed 2000/06/01; Revised 2006/11/15;
PMID: 10795453, status: MEDLINE (last retrieved date: 2/18/2009)
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MeSH Headings (categories) shown below.
Note: Bold headings indicate primary MeSH headings or qualifiers.
Associated Chemicals: Dental Implants (0) ; Polyurethanes (0)Related articles
These are the most related articles currently in our database:
- Strains recorded in a combined tooth-implant restoration: an in vivo study.
27 Feb 2005 - Feasibility and influence of the microgap of two implants placed in a non-submerged procedure: a five-year follow-up clinical trial.
30 May 2006 - Factors influencing marginal tissue remodeling around implants.
30 Oct 2003 - Bone reactions to longstanding functional load at implants: an experimental study in dogs.
30 Aug 2005 - Peri-implant bone loss as a function of tooth-implant distance.
30 Aug 2005 - Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis.
29 Nov 2004 - Screw loosening for standard and wide diameter implants in partially edentulous cases: 3- to 7-year longitudinal data.
30 Aug 2004 - AICRG, Part II: Crestal bone loss associated with the Ankylos implant: loading to 36 months.
30 Dec 2003 - Persistent acute inflammation at the implant-abutment interface.
27 Feb 2003 - A three-year follow-up report of a comparative study of ITI Dental Implants and Brånemark System implants in the treatment of the partially edentulous maxilla.
30 Dec 2003
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.
See a larger map of 100+ related articles.