A diagnostic expert system for structured reports, quality assessment, and training of residents in sonography.
Full Abstract
BACKGROUND: The quality of medical reports on diagnostic procedures has a considerable impact on the quality of medical care. Handwritten or otherwise unstructured reports tend to be incomplete, whereas structured questionnaires are of limited flexibility and not considered case-adequate. Thus, medical reports of this kind may promote an incomplete and misleading documentation and, therefore, be problematic with respect to their reliability. METHODS: SonoConsult (SC), an expert system for structured and case-adequate documentation of sonographic findings with an additional diagnostic component, was evaluated with respect to user acceptance and suitability for enhancing the quality of reports and supporting sonographic beginners. The expectations and the attitudes of the users toward the program were evaluated by anonymous questionnaires. The documentation of findings and the diagnostic conclusions in 103 free text reports made by experienced examiners were evaluated by subjecting their information to a subsequent input into SC. Free text reports were checked for information that was asked by SC but not mentioned in the reports. In a series of 150 cases, the system diagnoses were blinded during input of findings into SC-questionnaires and the examiners' diagnostic conclusions were compared with the uncovered SC-diagnoses with respect to forgotten diagnoses. RESULTS: The structured and data-driven acquisition of information by the program was well accepted by the users. However, only a medium interest in the system-delivered diagnoses was noted. The program-generated reports were characterized by a more detailed description of the findings and a higher number of diagnoses in comparison to the unstructured reports before introduction of SC as the only documentation system. When unaware of the system diagnoses, information was entered into the questionnaires, and SC generated some diagnoses which were not mentioned by the examiners in their conclusions. The possibility to inspect the system diagnoses led to an enhancement of the number of diagnoses the examiners mentioned in their conclusions. By contrast, the examiners meant that the influence of the program on their conclusions was minimal or dispensable. Beginners in sonography acknowledged that the program led them to perform a complete examination in an adequate sequence. CONCLUSION: An expert system for the data-driven, case-adequate information acquisition of abdominal ultrasound examinations may enhance the quality of the reports and, potentially, of the examinations at the same time. In addition, it may help beginners to learn a structured problem- and finding-adequate examination sequence.
Author information
Author/s: Huettig, Matthias (M); Buscher, Georg (G); Menzel, Thomas (T); Scheppach, Wolfgang (W); Puppe, Frank (F); Buscher, Hans-Peter (HP);
Affiliation: Clinic for Internal Medicine II, DRK-Kliniken Berlin-Köpenick, Germany.
Journal and publication information
Publication Type: Comparative Study; Journal Article
Journal: Medizinische Klinik (Munich, Germany : 1983) (Med Klin (Munich)), published in Germany. (Language: eng)
Reference: 2004-Mar; vol 99 (issue 3) : pp 117-22
Dates: Created 2004/03/16; Completed 2004/09/16; Revised 2006/11/15;
PMID: 15024483, status: MEDLINE (last retrieval date: 2/18/2009, IMS Date: )
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- [Establishing a quality management system according to DIN EN ISO 9001:2000 in an academic radiological department]
30 Jan 2003 - Quality monitoring, standardized documentation and management with a computerized system in oncology.
30 Dec 1996 - [Expert systems in medicine]
29 Jun 1996 - The radiology resident in difficulty.
30 Oct 1995 - Cross-institutional stability of behavioral criteria desirable for success in radiology residency.
27 Feb 1989 - The radiation therapy resident: a survey of motivating factors, degree of satisfaction and expectations.
30 May 1981 - Radiology residency training in diagnostic sonography: recommendations of the Society of Radiologists in Ultrasound.
30 Jul 1989 - Using a sonographic simulator to assess residents before overnight call.
30 Dec 2001 - Computerized extraction of coded findings from free-text radiologic reports. Work in progress.
30 Jan 1990 - An inexpensive distance learning solution for delivering high-quality live broadcasts.
4 Jul 2008
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.
See a large map of 100+ related articles.