PURPOSE: To evaluate the safety and the long-term clinical and hemodynamic results of primary stent placement of atherosclerotic calcified stenosis of the infrarenal aorta. MATERIAL AND METHODS: Between July 1996 and July 1999, 15 patients (nine male, si- female; mean age, 53.9 years) with symptomatic, calcified aortic stenosis were treated with primary stent placement. Patients underwent abdominal aortography and bilateral lower extremity arteriography. Follow-up was performed in all 15 patients. Technical success was defined as residual stenosis of less than 30% or a resting trans-systolic pressure gradient of less than 10 mm Hg after stent placement. Clinical patency was defined as the absence or improvement of symptoms after stent placement. Hemodynamic patency was defined as a normal triphasic Doppler waveform in the common femoral artery, an ankle-brachial index greater than 0.90, or the absence of a thigh-brachial pressure gradient at rest in either limb. RESULTS: Technical success was achieved in 13 of 15 patients. The two patients considered to be technical failures had resting trans-systolic pressure gradients of 12 and 13 mm Hg, respectively, after stent placement. After the mean follow-up of 36 months, primary clinical and hemodynamic patency rates were 85% and the secondary hemodynamic patency rate was 100%. Two of five symptomatic recurrences during the 36-month follow-up period (range, 12-46 months) were a result of aortic restenosis and were treated with repeated percutaneous transluminal angioplasty. None of the patients required aortic surgery. Complications of the primary procedure included one puncture site infection, one pseudoaneurysm, and one distal embolization, which delayed discharge of three patients. There was no morbidity during the secondary interventions. CONCLUSION: Primary stent placement as treatment of calcified infrarenal aortic stenosis proved to be safe and also provided durable long-term clinical improvement.

 

Author information

Author/s: Schedel, Hannes (H); Wissgott, Christian (C); Rademaker, Juergen (J); Steinkamp, Hermann J (HJ);

Affiliation: Reha-Klinik, Kellberg bei Passau, Department of Radiology, Berlin, Germany.

Journal and publication information

Publication Type: Comparative Study; Evaluation Studies; Journal Article

Journal: Journal of vascular and interventional radiology : JVIR (J Vasc Interv Radiol), published in United States. (Language: eng)

Reference: 2004-Apr; vol 15 (issue 4) : pp 353-9

Dates: Created 2004/04/05; Completed 2004/11/06; Revised 2006/11/15;

PMID: 15064338, status: MEDLINE (last retrieval date: 2/18/2009, IMS Date: )

Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.

External Links for this article
(including full text providers, if available):

Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.

This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.

MeSH headings (categories)

This article was linked to the MESH Headings shown below.

Related articles

These are the highest related articles currently in the database:

See 100+ related articles.

Related Article Map

12/30/1985
9/29/2008
Higher Relevance Score (47)
Lower Relevance Score (23)

Legend: - FREE Full text Article. - Abstract only. - Title only. More help.

See a large map of 100+ related articles.

© Advanogy LLC 2003-2009 - All rights reserved. Terms of Use | Contact Us | Index