| Research article summary (published 30 May 2006): |
Neonatal hearing screening: evaluation of tone-burst and click-evoked otoacoustic emission test criteria.
Full Abstract
OBJECTIVE:
Click-evoked otoacoustic emissions (CEOAEs) are widely used in universal neonatal hearing screening programs. A common finding in many such programs is a relatively high false-positive rate. This is often due to infant physiological noise adversely affecting the emission recording, leading to a "refer" screening outcome. In an attempt to reduce false-positive screening outcomes related to the effects of noise on otoacoustic emission response detection, tone-burst-evoked otoacoustic emissions (TBOAEs) were included in a neonatal hearing screening program because TBOAEs may elicit a greater signal-to-noise ratio than CEOAEs. The research project compared the pass/refer rate for a CEOAE-based test using established pass/refer criteria with the pass/refer rate for screening criteria that were based on TBOAE results alone or on combined CEOAE and TEOAE results.
DESIGN:
Neonates were recruited at the Hong Kong Adventist Hospital, and both CEOAEs and TBOAEs were performed. Six passing criteria were used in this study, based on CEOAEs only; CEOAEs plus 1 kHz TBOAEs; CEOAEs plus 2 kHz TBOAEs; CEOAEs plus 3 kHz TBOAEs; CEOAEs plus 1, 2, and 3 kHz TBOAEs; and TBOAEs only.
RESULTS:
Data from 298 neonates (546 ears) were obtained. Criteria set 1, using CEOAEs only, demonstrated a pass rate of 79.1%, and 114 ears were referred. Criteria set 2, using CEOAEs together with TBOAEs recorded at 1 kHz, passed 39 more ears than Protocol 1, and the pass rate was 86.3%. Hence, the overall referral rate for total number of screened ears decreased by 7.2 percentage points. Criteria set 3, using CEOAEs together with TBOAEs recorded at 2 kHz, and Criteria set 4, using CEOAEs in conjunction with TBOAEs recorded at 3 kHz, gave pass rates similar to Criteria set 1. Criteria set 5, using TBOAE information at frequencies where CEOAEs were not rated as "pass," raised the pass rate from 79.1 to 87.6%, reducing the overall referral rate by 8.5 percentage points. Criteria set 6, in which neonates were screened with TBOAEs recorded at 1, 2, and 3 kHz, gave a pass rate of 78.4%, similar to results for the CEOAE-only procedure.
CONCLUSIONS:
Both Criteria sets 2 and 5, which combined CEOAE and TBOAE recordings, gave significantly higher pass rates than Criteria sets 1, 3, 4, and 6. The results suggest that the introduction of combined CEOAE and TBOAE protocols may assist in the reduction of refer outcomes, and hence the false-positive rates, of neonatal hearing screening programs.
Learn Faster Today Improve your study skills
Author information
Author/s: McPherson, B (B); Li, S F (SF); Shi, B X (BX); Tang, J L F (JL); Wong, B Y K (BY);
Affiliation: Division of Speech and Hearing Sciences, University of Hong Kong, Hong Kong, China. dbmcpher(-atsign-)hkucc.hku.hk
Journal and publication information
Publication Type: Journal Article; Research Support, Non-U.S. Gov't
Journal: Ear and hearing (Ear Hear), published in United States. (Language: eng)
Reference: 2006-Jun; vol 27 (issue 3) : pp 256-62
Dates: Created 2006/05/04; Completed 2006/10/19; Revised 2006/11/15;
PMID: 16672794, status: MEDLINE (last retrieval date: 12/26/2008)
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article (including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: recommendations for policy, practice, and research.
29 Nov 2005 - Universal neonatal hearing screening: the Siena (Italy) experience on 19,700 newborns.
18 Feb 2007 - Effectiveness and efficiency of a universal newborn hearing screening in Germany.
30 Dec 2005 - Comparison of hearing screening programs between one step with transient evoked otoacoustic emissions (TEOAE) and two steps with TEOAE and automated auditory brainstem response.
30 Oct 2005 - A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: research design and results of the study.
29 Nov 2005 - A multisite study to examine the efficacy of the otoacoustic emission/automated auditory brainstem response newborn hearing screening protocol: results of visual reinforcement audiometry.
29 Nov 2005 - Initial audiologic assessment of infants referred from well baby, special care, and neonatal intensive care unit nurseries.
30 May 2006 - Voluntary progress toward universal newborn hearing screening.
30 Jan 2004 - Further examination of infants referred from newborn hearing screening.
29 Sep 2004 - [Neonatal hearing loss screening: our results three years after starting the program]
30 Jan 2005
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.
See a large map of 100+ related articles.