| Research article summary (published 29 Apr 2009): |
Precision-to-tolerance capability: an important consideration in tight glucose control.
Full Abstract
OBJECTIVE: To assess clinical implications of bias and variance of point-of-care glucometric measurements in cardiac surgery patients with wide variations in postoperative hematocrit. METHODS: Point-of-care glucose measurements were compared with values from laboratory analysis of the same sample of whole blood obtained from cardiac patients early on postoperative days 1 and 2. Twenty nurses collected 89 arterial blood samples from 58 patients during a 4-month period. Bias was measured by using difference scores between paired measurements. Patients were grouped within 5% increments according to hematocrit, and analysis of variance was used to test for differences. Variation was analyzed by precision-to-tolerance analysis within 3 euglycemic tolerance ranges. RESULTS: Laboratory glucose values were 62 to 224 mg/dL; point-of-care measures were 83 to 253 mg/dL. Bias was 10.85 mg/dL across all hematocrit groups. Pairs of laboratory and point-of-care glucose values differed significantly (t(174) = 10.03; P < .001). Bias increased from -2.83 mg/dL for patients with hematocrits exceeding 39% to +16.71 mg/dL for patients with hematocrits between 20% and 24%. The standard deviation of difference scores was 11.59 mg/dL overall. The difference between 5% hematocrit groups was significant (F(4) = 4.11; P = .004). Precision-to-tolerance capability ratios for specification limits of 70 to 300, 90 to 140, and 80 to 110 mg/dL were 0.30, 1.39, and 2.32, respectively. CONCLUSIONS: The direction of bias change between hematocrit groupings was the direction predicted in the manufacturer's information. Precision-to-tolerance measures indicated that the point-of-care equipment was not suitable for testing glucose within the planned "tighter" glycemic standards.
Author information
Author/s: Prinzing, Catherine (C); Rosenlund, Sarah (S); Sukeena, Vicki (V); Malinowski, Cynthia (C); Wise, Lowell C (LC);
Affiliation: Trinity Health-Saint Alphonsus Regional Medical Center in Boise, Idaho. USA.
Journal and publication information
Publication Type: Comparative Study; Journal Article
Journal: American journal of critical care : an official publication, American Association of Critical-Care Nurses (Am J Crit Care), published in United States. (Language: eng)
Reference: 2009-May; vol 18 (issue 3) : pp 232-9
Dates: Created 2009/05/04; Completed 2009/07/07;
PMID: 19411583, status: MEDLINE (last retrieved date: 7/24/2009)
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MeSH Headings (categories) shown below.
Note: Bold headings indicate primary MeSH headings or qualifiers.
Associated Chemicals: Blood Glucose (0)Related articles
These are the most related articles currently in our database:
- [Setting up a quality assurance system for the management of blood glucose monitoring in hospital units]
30 Aug 1998 - Importance of sample size in hospital point-of-care glucose measurements.
30 Dec 2007 - [Evaluation of GLUCOCARD X-METER glucose monitoring system]
30 Jan 2008 - Analytical validation of the new plasma calibrated Accu-Chek Test Strips (Roche Diagnostics).
30 Dec 2005 - Effect of adverse storage conditions on performance of glucometer test strips.
30 Dec 2004 - Multicenter study of oxygen-insensitive handheld glucose point-of-care testing in critical care/hospital/ambulatory patients in the United States and Canada.
27 Feb 1998 - Accuracy evaluation of a new glucometer with automated hematocrit measurement and correction.
29 Mar 2005 - The periodic health examination. Of what real value is it?
30 Oct 1983 - Evaluation of the Abbott PCx (R) point of care glucose analyzer in a pediatric hospital.
30 May 2000 - Should diabetes healthcare abandon its gold standard?
30 Oct 2007
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.
See a larger map of 100+ related articles.