Find-Health-Articles.com - making medical research available to everyone
Research article summary (published 29 Apr 2009):

Precision-to-tolerance capability: an important consideration in tight glucose control.

Full Abstract

OBJECTIVE: To assess clinical implications of bias and variance of point-of-care glucometric measurements in cardiac surgery patients with wide variations in postoperative hematocrit. METHODS: Point-of-care glucose measurements were compared with values from laboratory analysis of the same sample of whole blood obtained from cardiac patients early on postoperative days 1 and 2. Twenty nurses collected 89 arterial blood samples from 58 patients during a 4-month period. Bias was measured by using difference scores between paired measurements. Patients were grouped within 5% increments according to hematocrit, and analysis of variance was used to test for differences. Variation was analyzed by precision-to-tolerance analysis within 3 euglycemic tolerance ranges. RESULTS: Laboratory glucose values were 62 to 224 mg/dL; point-of-care measures were 83 to 253 mg/dL. Bias was 10.85 mg/dL across all hematocrit groups. Pairs of laboratory and point-of-care glucose values differed significantly (t(174) = 10.03; P < .001). Bias increased from -2.83 mg/dL for patients with hematocrits exceeding 39% to +16.71 mg/dL for patients with hematocrits between 20% and 24%. The standard deviation of difference scores was 11.59 mg/dL overall. The difference between 5% hematocrit groups was significant (F(4) = 4.11; P = .004). Precision-to-tolerance capability ratios for specification limits of 70 to 300, 90 to 140, and 80 to 110 mg/dL were 0.30, 1.39, and 2.32, respectively. CONCLUSIONS: The direction of bias change between hematocrit groupings was the direction predicted in the manufacturer's information. Precision-to-tolerance measures indicated that the point-of-care equipment was not suitable for testing glucose within the planned "tighter" glycemic standards.

 

Author information

Author/s: Prinzing, Catherine (C); Rosenlund, Sarah (S); Sukeena, Vicki (V); Malinowski, Cynthia (C); Wise, Lowell C (LC);

Affiliation: Trinity Health-Saint Alphonsus Regional Medical Center in Boise, Idaho. USA.

Journal and publication information

Publication Type: Comparative Study; Journal Article

Journal: American journal of critical care : an official publication, American Association of Critical-Care Nurses (Am J Crit Care), published in United States. (Language: eng)

Reference: 2009-May; vol 18 (issue 3) : pp 232-9

Dates: Created 2009/05/04; Completed 2009/07/07;

PMID: 19411583, status: MEDLINE (last retrieved date: 7/24/2009)

Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.

External Links for this article
(including full text providers, if available):

Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.

This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.

MeSH headings (categories)

This article was linked to the MeSH Headings (categories) shown below.

Note: Bold headings indicate primary MeSH headings or qualifiers.

Associated Chemicals: Blood Glucose (0)

Related articles

These are the most related articles currently in our database:

See 100+ related articles.

Related Article Map

10/30/1983
2/13/2008
Higher Relevance Score (100)
Lower Relevance Score (49)

Legend: - FREE Full text Article. - Abstract only. - Title only. More help.

See a larger map of 100+ related articles.

© Advanogy LLC 2003-2010 - All rights reserved. Terms of Use | Contact Us | Index