Find-Health-Articles.com - making medical research available to everyone
Research article summary (published 30 Aug 2009):

Feasibility of k-t BLAST for BOLD fMRI with a spin-echo based acquisition at 3 T and 7 T.

Full Abstract

OBJECTIVES: This study tested the feasibility of applying k-t BLAST to blood oxygen level dependent functional MRI of the brain at 3 Tesla (T) and at 7 T. Shorter echo train lengths, achieved through the application of k-t BLAST, are expected to counteract increased sensitivity to inhomogeneities in B0 at higher magnetic field strengths, especially in echo planar images, and reduce the relatively long acquisition times and high RF power deposition in spin-echo based methods. MATERIALS AND METHODS: k-t BLAST was combined with displaced UFLARE at 3 T and 7 T. Temporal and spatial fidelity of k-t BLAST were investigated using a test object, in which localized variations in signal intensity mimic activation-induced signal changes. fMRI was performed using typical box-car design finger tapping. In a separate analysis full k-space data were decimated to simulate k-t BLAST acquisitions and compare results with the fully sampled data, thereby avoiding physiological and noise differences between acquisitions. RESULTS: Activation can be detected at under-sampling factors as high as 16, whereas appropriately reconstructed data, under-sampled at factors below 8 entail insignificant loss of sensitivity and considerable reductions in acquisition times and RF power deposition. CONCLUSIONS: k-t BLAST is compatible with fMRI acquisitions and opens up possibilities including distortion-free T2*-weighted blood oxygen level dependent fMRI with displaced UFLARE at high magnetic field strengths.

 

Author information

Author/s: Utting, Jane F (JF); Kozerke, Sebastian (S); Luechinger, Roger (R); Schnitker, Ralph (R); Vohn, René (R); Bhanniny, Rani (R); Tilbian, Maral (M); Niendorf, Thoralf (T);

Affiliation: IZKF-BIOMAT, Faculty of Medicine, RWTH-Aachen, Aachen, Germany. j.utting(-atsign-)nhs.net

Journal and publication information

Publication Type: Evaluation Studies; Journal Article

Journal: Investigative radiology (Invest Radiol), published in United States. (Language: eng)

Reference: 2009-Sep; vol 44 (issue 9) : pp 495-502

Dates: Created 2009/08/20; Completed 2009/11/05;

PMID: 19652607, status: MEDLINE (last retrieval date: 11/5/2009, IMS Date: )

Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.

External Links for this article
(including full text providers, if available):

Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.

This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.

MeSH headings (categories)

This article was linked to the MESH Headings shown below.

Associated Chemicals: Spin Labels (0)

Related articles

These are the highest related articles currently in the database:

See 100+ related articles.

Related Article Map

7/28/1993
10/30/2007
Higher Relevance Score (100)
Lower Relevance Score (74)

Legend: - FREE Full text Article. - Abstract only. - Title only. More help.

See a large map of 100+ related articles.

© Advanogy LLC 2003-2009 - All rights reserved. Terms of Use | Contact Us | Index