Sensitivity and specificity of the Heidelberg Retina Tomograph II Version 3.0 in a population-based study: the Tajimi Study.

Full Abstract

PURPOSE: To evaluate the sensitivity and specificity of the 3 glaucoma classification programs, the FS Mikelberg discriminant function (FSM), Moorfields Regression Analysis (MRA), and Glaucoma Probability Score (GPS) of version 3.0 of the Heidelberg Retina Tomograph (HRT) II (Heidelberg Engineering, Dossenheim, Germany), in a population-based setting for the first time. DESIGN: Population-based cross-sectional study. PARTICIPANTS: One randomly chosen eye of each subject without glaucoma, subject with glaucoma, and subject with suspected glaucoma with reliable HRT II measurements from the Tajimi study (2297 eyes of 2297 subjects) were included for analysis. METHODS: Glaucoma was diagnosed by the optic disc and visual field findings according to the criteria of the International Society of Geographical and Epidemiological Ophthalmology. The sensitivity and specificity of FSM, MRA, and GPS were calculated. Characteristics of erroneously diagnosed glaucoma (false-negative) eyes and factors that influenced specificity with the 3 programs were investigated. MAIN OUTCOME MEASURES: Sensitivity and specificity of FSM, MRA, and GPS. RESULTS: Sensitivity and specificity varied significantly among the 3 programs: 59.1%, 39.4%, and 65.2% (P = 0.02 approximately 0.003, chi-square test), and 86.7%, 96.1%, and 83.0% (P<0.0001) with FMS, MRA, and GPS, respectively. MRA gave the lowest sensitivity but the highest specificity. Positive predictive values for these programs ranged between 0.10 and 0.23, whereas negative predictive values ranged between 0.98 and 0.99. False-negative eyes had significantly better visual field indexes (P<0.01 approximately 0.002, Mann-Whitney U test) and smaller cup and larger rim parameters compared with true-positive glaucoma eyes. Older age and hyperopia were negatively correlated with the specificity of GPS but not with that of FMS and MRA. Larger disc area was significantly associated with decreased specificity of all programs. CONCLUSIONS: In a population-based setting, the sensitivity of the HRT II was unsatisfactory with any of the classification programs, whereas specificity was satisfactory. A significant percentage of the glaucoma discs were labeled as normal, and eyes in the earlier stage of the disease appear to be more likely to be misdiagnosed as normal. Factors such as age, refraction, and disc area had an influence on specificity, but the degree of its influence was different for each classification program.

 

Author information

Author/s: Saito, Hitomi (H); Tsutsumi, Tae (T); Araie, Makoto (M); Tomidokoro, Atsuo (A); Iwase, Aiko (A);

Affiliation: Department of Ophthalmology, University of Tokyo, Graduate School of Medicine, Tokyo, Japan.

Journal and publication information

Publication Type: Comparative Study; Journal Article

Journal: Ophthalmology (Ophthalmology), published in United States. (Language: eng)

Reference: 2009-Oct; vol 116 (issue 10) : pp 1854-61

Dates: Created 2009/10/05; Completed 2009/10/16;

PMID: 19660814, status: MEDLINE (last retrieval date: 10/16/2009, IMS Date: )

Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.

External Links for this article
(including full text providers, if available):

Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.

This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.

MeSH headings (categories)

This article was linked to the MESH Headings shown below.

Related articles

These are the highest related articles currently in the database:

See 100+ related articles.

Related Article Map

3/19/2003
10/30/2008
Higher Relevance Score (100)
Lower Relevance Score (77)

Legend: - FREE Full text Article. - Abstract only. - Title only. More help.

See a large map of 100+ related articles.

© Advanogy LLC 2003-2009 - All rights reserved. Terms of Use | Contact Us | Index