| Research article summary (published 30 Aug 2009): |
Effect of the method to measure levels of glycated hemoglobin on individual clinical decisions: comparison of an immunoassay with high-performance liquid chromatography.
Full Abstract
Our objective was to compare in a prospective study the clinical performance of the reference and an alternative method to measure blood levels of glycated hemoglobin. A total of 178 samples from patients with diabetes were tested by both methods, and results were analyzed for correlation and comparison of sensitivity, specificity, and positive and negative predictive values to classify patients according to glycemic control. There was a significant linear correlation between methods (r = 0.645; P < .0001); the sensitivity, specificity, and positive and negative predictive values of the alternative method to identify patients with controlled and uncontrolled status were as follows: controlled, 88%, 78%, 77%, and 88%; and uncontrolled, 78%, 88%, 88%, and 77%, respectively. Results show that although the results of both methods show a statistically significant correlation, the ability of the alternative method to correctly classify individual patients according to glycemic control status is far from optimal.
Author information
Author/s: García-Alcalá, Héctor (H); Ruiz-Argüelles, Alejandro (A); Cedillo-Carvallo, Beatriz (B);
Affiliation: Faculty of Medicine, UPAEP University, Puebla, PUE 72530, México.
Journal and publication information
Publication Type: Clinical Trial; Comparative Study; Journal Article
Journal: American journal of clinical pathology (Am J Clin Pathol), published in United States. (Language: eng)
Reference: 2009-Sep; vol 132 (issue 3) : pp 332-5
Dates: Created 2009/08/18; Completed 2009/09/04;
PMID: 19687308, status: MEDLINE (last retrieval date: 9/4/2009, IMS Date: )
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.