|
|
| Research article summary (published 30 Aug 2009): |
Jitter recordings with concentric needle electrodes.
Full Abstract
Neuromuscular jitter is generally recorded with a single fiber (SF) electromyography (EMG) electrode. Due to concern about using reusable needle electrodes, an acceptable alternative for the SF electrode has been sought. This is a review of the issues involved in using disposable concentric needle (CN) electrodes to measure jitter. Signals recorded with CN electrodes frequently represent the summation of many single fiber action potentials, which will decrease the apparent jitter. The influence of these artifacts on the final result also depends on the analysis method. Reference values obtained with CN electrodes correlate with SF EMG values, but they are a few microseconds lower. Overall results show that the CN method is a good alternative to SFEMG and will facilitate the use of jitter analysis. The results must be interpreted with caution, particularly in borderline cases, but they may be acceptable for clinical use when SF electrodes cannot be used.
Author information
Author/s: Stålberg, Erik V (EV); Sanders, Donald B (DB);
Affiliation: Department of Clinical Neurophysiology, University Hospital, Uppsala, S-751 85 Sweden. stalberg.erik(-atsign-)gmail.com
Journal and publication information
Publication Type: Journal Article; Review
Journal: Muscle & nerve (Muscle Nerve), published in United States. (Language: eng)
Reference: 2009-Sep; vol 40 (issue 3) : pp 331-9
Dates: Created 2009/08/31; Completed 2009/10/06;
PMID: 19705424, status: MEDLINE (last retrieval date: 10/6/2009, IMS Date: )
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- Reliability of measurement of muscle fiber conduction velocity using surface EMG.
30 Dec 1998 - Physiology and interpretation of the electromyogram.
30 Aug 1996 - Muscle-fiber conduction velocity estimated from surface EMG signals during explosive dynamic contractions.
30 May 2004 - Sensitivity of surface EMG-based conduction velocity estimates to local tissue in-homogeneities--influence of the number of channels and inter-channel distance.
13 Mar 2005 - Single-fiber electromyography.
29 Apr 2003 - Technical artifact simulating "motor axonopathy".
30 Mar 1992 - Analysis of interference patterns with Willison's method. Clinical uses, effect of load, dynamic studies.
30 Oct 1985 - Assessment of diaphragm function.
29 Apr 1998 - Clinical applications of surface electromyography in neuromuscular disorders.
29 Jun 2005 - Influence of anatomical, physical, and detection-system parameters on surface EMG.
30 May 2002
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.
See a large map of 100+ related articles.