| Research article summary (published 29 Sep 2009): |
Radrue method for reconstruction of external photon doses for Chernobyl liquidators in epidemiological studies.
Full Abstract
Between 1986 and 1990, several hundred thousand workers, called "liquidators" or "clean-up workers," took part in decontamination and recovery activities within the 30-km zone around the Chernobyl nuclear power plant in Ukraine, where a major accident occurred in April 1986. The Chernobyl liquidators were mainly exposed to external ionizing radiation levels that depended primarily on their work locations and the time after the accident when the work was performed. Because individual doses were often monitored inadequately or were not monitored at all for the majority of liquidators, a new method of photon (i.e., gamma and x rays) dose assessment, called "RADRUE" (Realistic Analytical Dose Reconstruction with Uncertainty Estimation), was developed to obtain unbiased and reasonably accurate estimates for use in three epidemiologic studies of hematological malignancies and thyroid cancer among liquidators. The RADRUE program implements a time-and-motion dose-reconstruction method that is flexible and conceptually easy to understand. It includes a large exposure rate database and interpolation and extrapolation techniques to calculate exposure rates at places where liquidators lived and worked within approximately 70 km of the destroyed reactor. The RADRUE technique relies on data collected from subjects' interviews conducted by trained interviewers, and on expert dosimetrists to interpret the information and provide supplementary information, when necessary, based upon their own Chernobyl experience. The RADRUE technique was used to estimate doses from external irradiation, as well as uncertainties, to the bone marrow for 929 subjects and to the thyroid gland for 530 subjects enrolled in epidemiologic studies. Individual bone marrow dose estimates were found to range from less than one muGy to 3,300 mGy, with an arithmetic mean of 71 mGy. Individual thyroid dose estimates were lower and ranged from 20 muGy to 507 mGy, with an arithmetic mean of 29 mGy. The uncertainties, expressed in terms of geometric standard deviations, ranged from 1.1 to 5.8, with an arithmetic mean of 1.9.
Author information
Author/s: Kryuchkov, Victor (V); Chumak, Vadim (V); Maceika, Evaldas (E); Anspaugh, Lynn R (LR); Cardis, Elisabeth (E); Bakhanova, Elena (E); Golovanov, Ivan (I); Drozdovitch, Vladimir (V); Luckyanov, Nickolas (N); Kesminiene, Ausrele (A); Voillequé, Paul (P); Bouville, André (A);
Affiliation: Burnasyan Federal Medical Biophysical Center (formerly Institute of Biophysics), 46 Zhivopisnaya Street, 123182, Moscow, Russian Federation.
Grants: 1R01CCR015763-02 (Agency:PHS HHS) ; Y2-AL-5077 (Agency:PHS HHS) ; Y3-CO-5117 (Agency:NCI NIH HHS)
Journal and publication information
Publication Type: Journal Article; Research Support, N.I.H., Intramural; Research Support, Non-U.S. Gov't; Research Support, U.S. Gov't, Non-P.H.S.; Research Support, U.S. Gov't, P.H.S.
Journal: Health physics (Health Phys), published in United States. (Language: eng)
Reference: 2009-Oct; vol 97 (issue 4) : pp 275-98
Dates: Created 2009/09/10; Completed 2009/09/28;
PMID: 19741357, status: MEDLINE (last retrieval date: 9/28/2009, IMS Date: )
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- Some useful data for narrow beam dosimetry.
30 Dec 2000 - Thyroid dosimetry in the western trace of the Chernobyl accident plume.
30 Dec 2003 - [Cytogenetical indices in remote times after acute irradiation of people. The computer method of retrospective dose estimation]
30 Dec 2006 - [In vivo dosimetry for the evaluation of the irradiation dose for the thyroid after prophylactic cerebral irradiation in leukemia of children]
30 Dec 1996 - Clinically useful marrow dosimetry for targeted radionuclide therapy.
30 Mar 2005 - Mouse models for internal radiation dosimetry.
30 Oct 1999 - Rapid radiographic film calibration for IMRT verification using automated MLC fields.
29 Sep 2002 - Estimating individual thyroid doses for a case-control study of childhood thyroid cancer in Bryansk Oblast, Russia.
30 Dec 2003 - Dosimetric characteristics of linear accelerator photon beams with small monitor unit settings.
30 Oct 2008 - Computer algebra for x-ray spectral reconstruction between 6 and 25 MV.