| Research article summary (published 30 Jul 2009): |
Biotribological investigation of a multi-tube foot for traction generation in a medical microrobot.
Full Abstract
In recent years, efforts to develop microrobots for medical applications have been expanding. One of the key design issues in such microrobots is to attain adequate frictional interaction between the robotic foot and the organ tissue. In particular, it is important to generate the necessary frictional force without damaging the tissue. In this work, a design for the robotic foot was proposed on the basis of the frictional behaviour of a tube structure. Fundamental experiments were initially performed to understand the biotribological behaviour of the tube and rod structures. The design was then modified to a multi-tube structure to achieve adequate frictional behaviour. Biotribological investigation of a multi-tube foot in contact with a small intestine specimen of a pig was conducted using a pin-on-reciprocator type biotribotester. It was found that there is an optimum number and arrangement of the tubes for generating high frictional force. Experimental results showed that a nine-tube foot had the highest initial friction coefficient of about 1.5. The major frictional mechanism was determined to be interlocking between the tubes and the surface structures of the intestine specimen. The results of this work will aid the optimum design of frictional surface for medical microrobots and other biological devices.
Author information
Author/s: Kim, Y T (YT); Kim, D E (DE);
Affiliation: Department of Mechanical Engineering, Yonsei University, Seoul, Republic of Korea.
Journal and publication information
Publication Type: Journal Article; Research Support, Non-U.S. Gov't
Journal: Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine (Proc Inst Mech Eng H), published in England. (Language: eng)
Reference: 2009-Aug; vol 223 (issue 6) : pp 677-86
Dates: Created 2009/09/11; Completed 2009/10/07;
PMID: 19743634, status: MEDLINE (last retrieval date: 10/7/2009, IMS Date: )
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- A novel surgical robot design: minimizing the operating envelope within the sterile field.
30 Dec 2005 - Initial design of a bacterial actuated microrobot for operations in an aqueous medium.
30 Dec 2005 - Improved traction for a mobile robot traveling on the heart.
30 Dec 2005 - A new impact actuator using linear momentum exchange of inertia mass.
30 Oct 2002 - Vision-based sensor for real-time measuring of surface traction fields.
30 Dec 2004 - Development of safe mechanism for surgical robots using equilibrium point control method.
30 Dec 2005 - Friction identification in mechatronic systems.
30 Mar 2004 - Optimization of a spherical mechanism for a minimally invasive surgical robot: theoretical and experimental approaches.
29 Jun 2006 - A prototype rehabilitation device with variable resistance and joint motion control.
17 Aug 2005 - An artificial muscle actuator for biomimetic underwater propulsors.
3 Jun 2007
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.