|
|
| Research article summary (published 29 Sep 2009): |
Automated assay for fondaparinux (Arixtra) on the Dade Behring BCS XP.
Full Abstract
An assay for fondaparinux (Arixtra) is described based on a modified commercial assay for heparin. The assay is automated on a Dade Behring BCS XP (Siemens Healthcare Diagnostics, Deerfield, IL) and uses the inhibition of activated factor X to quantitate the drug. The assay was unaffected by platelet contamination or the presence of warfarin. The assay was affected by the antithrombin level, and the value obtained in the assay decreased significantly when the antithrombin level was less than 60%. The assay is, however, not specific for fondaparinux. Specimens containing unfractionated or low-molecular-weight heparin will yield results by this assay that will not be an accurate estimation of concentration.
Author information
Author/s: Sanfelippo, Michael J (MJ); Tillema, Veronica B (VB);
Affiliation: Department of Hematology/Coagulation Services, Marshfield Labs, Marshfield Clinic, Marshfield, WI 54449, USA.
Journal and publication information
Publication Type: Journal Article; Research Support, Non-U.S. Gov't
Journal: American journal of clinical pathology (Am J Clin Pathol), published in United States. (Language: eng)
Reference: 2009-Oct; vol 132 (issue 4) : pp 608-12
Dates: Created 2009/09/18; Completed 2009/10/01;
PMID: 19762539, status: MEDLINE (last retrieval date: 10/1/2009, IMS Date: )
Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.
External Links for this article
(including full text providers, if available):
Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.
This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.
MeSH headings (categories)
This article was linked to the MESH Headings shown below.
Related articles
These are the highest related articles currently in the database:
- Two sensitive and rapid chromogenic assays of fondaparinux sodium (Arixtra) in human plasma and other biological matrices.
30 Dec 2002 - Determination of factor X and heparin with chromogenic substrate.
30 Dec 1981 - Development and clinical evaluation of two chromogenic substrate methods for monitoring fondaparinux sodium.
30 May 2006 - Heparin and other sulfated polyanions: their interaction with the blood platelet.
30 Dec 1980 - Heparin cofactor II activity in plasma: application of an automated assay method to the study of a normal adult population.
30 Dec 1985 - Quick tests for the determination of ammonia in poultry litter.
30 Aug 2002 - [Automated analyser of organ cultured corneal endothelial mosaic]
29 Apr 2002 - Evaluation of an automated commercial immunoluminometric assay for alpha-foetoprotein.
27 Feb 1991 - A continuous-flow (AutoAnalyzer II) procedure for measuring erythrocyte transketolase activity.
30 Oct 1982 - Evaluation of some fluorogenic substrates for continuous assay of aminopeptidase P.
30 Oct 1997
Related Article Map
Legend:
- FREE Full text Article.
- Abstract only.
- Title only. More help.
See a large map of 100+ related articles.