Research article summary (published 29 Sep 2009):

Biomechanical and morphological corneal response to placement of intrastromal corneal ring segments for keratoconus.

Full Abstract

PURPOSE: To evaluate the biomechanical and morphological changes in keratoconic corneas after Intacs intrastromal corneal ring segment (ICRS) implantation. SETTING: Department of Ophthalmology, National Reference Center for Keratoconus, Bordeaux University, Bordeaux, France. METHODS: Keratoconic eyes were retrospectively analyzed after ICRS implantation; preoperative and 6-month postoperative evaluation were done using the Ocular Response Analyzer (ORA) and the Orbscan II topographer. Biomechanical parameters included corneal hysteresis (CH), the corneal resistance factor (CRF), and other parameters extracted from the signal curves. Morphological parameters included simulated keratometry and the cone location magnitude index from the axial map (aCLMI) and tangential map (tCLMI). Parameters were extracted using software designed to read and process topographic maps. RESULTS: There were no significant differences between preoperatively and postoperatively in mean CH (7.7 mm Hg +/- 1.4 [SD] versus 7.4 +/- 1.4 mm Hg) or mean CRF (6.6 +/- 1.8 mm Hg versus 6.1 +/- 1.4 mm Hg). Only 2 ORA signal parameters were significantly different. Topographic parameters with significant decreases were minimum central keratometry (K) (mean change -5.8 +/- 2.9 diopters [D]) (P<.001), minimum central K (mean change -5.8 +/- 2.3 D) (P<.001), mean aCLMI (9.6 +/- 2.7 preoperatively versus 7.7 +/- 2.5 postoperatively) (P<.009), and mean tCLMI (18.9 +/- 2.8 versus 12.9 +/- 4.4) (P<.002). The only significant correlation between biomechanical and topographic parameters was postoperative ORA infrared signal peak 1 and postoperative aCLMI. CONCLUSIONS: Intrastromal corneal ring implantation significantly decreased corneal curvature, with preoperative values predicting magnitude of change. However, it did not alter the viscoelastic biomechanical parameters of CH and CRF.

 

Author information

Author/s: Dauwe, Caroline (C); Touboul, David (D); Roberts, Cynthia J (CJ); Mahmoud, Ashraf M (AM); Kérautret, Julien (J); Fournier, Pierre (P); Malecaze, François (F); Colin, Joseph (J);

Affiliation: Department of Ophthalmology, Reference National Centers for Keratoconus, Bordeaux University, France.

Journal and publication information

Publication Type: Journal Article

Journal: Journal of cataract and refractive surgery (J Cataract Refract Surg), published in United States. (Language: eng)

Reference: 2009-Oct; vol 35 (issue 10) : pp 1761-7

Dates: Created 2009/09/28; Completed 2009/10/30;

PMID: 19781473, status: MEDLINE (last retrieval date: 10/30/2009, IMS Date: )

Sourced from the National Library of Medicine. Abstract text and other information may be subject to copyright.

External Links for this article
(including full text providers, if available):

Click Electronic Full-text Provider Links to see options for finding the electronic full text links to this article. Note there may be a subscription or fee required for access to the full text. See our FAQ for information on finding FREE full text articles.

This article may also be located in paper journal collections available in many libraries. Use the Journal and Publication Information above to find the full article.

MeSH headings (categories)

This article was linked to the MESH Headings shown below.

Associated Chemicals: Polymethyl Methacrylate (9011-14-7)

Related articles

These are the highest related articles currently in the database:

See 100+ related articles.